Mobile ESS Linked with
Power Generation Complex
![]() | The power plant–linked mobile ESS is an eco-friendly energy storage system based on EV batteries, providing a flexible power solution that overcomes the limitations of fixed ESS units. With mobility and scalability, it ensures stable power supply in demand areas where power quality is critical—such as data centers and small to mid-sized industrial complexes—and effectively responds to output fluctuations in renewable energy plants. As a sustainable power infrastructure for carbon neutrality, it is well suited for smart grid and microgrid environments. |

01 Mobile ESS
| System Configuration PCS, ESS, BMS, EMS, Cooling Unit, Communication Equipment, Automatic Fire Suppression System, Circuit Breaker, Security Camera, Grounding System | ||
| Battery Capacity 400kW | PCS Output 200kW | Mobile ESS Weight 4.4t |
| Operating Voltage DC 600-1000V | Vehicle Specification Medium Truck, 4.5 t | |
02 Charging Station
| Output AC Max. 22 kW / DC Max. 75 kW (200–1000 V, 200 A) | ||
| Charging Method AC Slow or DC Fast | Connectors Type1, Type2, CCS1, CCS2, CHAdeMO | |
| Input Power Three-phase 380 V 60 Hz | Communication CAN, RS485, Modbus TCP / Built-in BMS | |
03 Lithium-Ion Battery Pack
| Rated Voltage 358V | BMS Functions SoC/SoH Estimation, Cell Monitoring, Fault Alarms, Relay Control, Communication Integration | |
| Battery Capacity 66.4kWh | Protection Features Overcharge, Overdischarge, Overcurrent, and Overtemperature Protection | |
| Maximum Current 200A | Communication CAN, RS485, Modbus TCP | |
04 Vehicle Charger
| DC Output Voltage 600A | DC Output Current 200A | Power Input AC 3-phase 380 V, 60 Hz |
| Communication CAN, RS485, Modbus TCP | Charging Method AC Slow (Max. 22 kW) + DC Fast (Max. 125 kW) | |
| Protection Rating IP65 | Connectors Type1, Type2, CCS1, CCS2, CHAdeMO | |
05 Mobile ESS UI
Main Features
| Platform Android, iOS / Web, Local Server |
| Connection Ethernet / VPN / Cloud Integration | |
| Features Map Integration, Lightweight App / Dashboard Layout, Multi-Device Support |
Mobile ESS Linked with
Power Generation Complex
![]() | The power plant–linked mobile ESS is an eco-friendly energy storage system based on EV batteries, providing a flexible power solution that overcomes the limitations of fixed ESS units. With mobility and scalability, it ensures stable power supply in demand areas where power quality is critical—such as data centers and small to mid-sized industrial complexes—and effectively responds to output fluctuations in renewable energy plants. As a sustainable power infrastructure for carbon neutrality, it is well suited for smart grid and microgrid environments. |

01
Mobile ESS
| System Configuration PCS, ESS, BMS, EMS, Cooling Unit, Communication Equipment, Automatic Fire Suppression System, Circuit Breaker, Security Camera, Grounding System | ||
| Battery Capacity 400kW | PCS Output 200kW | Operating Voltage DC 600-1000V |
| Vehicle Specification Medium Truck, 4.5t | Mobile ESS Weight 4.4t | |
02
Charging Station
| Output AC Max. 22 kW / DC Max. 75 kW (200–1000 V, 200 A) | ||
| Charging Method AC Slow or DC Fast | Connectors Type1, Type2, CCS1, CCS2, CHAdeMO | |
| Input Power Three-phase 380V 60Hz | Communication CAN, RS485, Modbus TCP / Built-in BMS | |
03
Lithium-Ion Battery Pack
| Rated Voltage 358V | BMS Functions SoC/SoH Estimation, Cell Monitoring, Fault Alarms, Relay Control, Communication Integration | |
| Battery Capacity 66.4kWh | Protection Features Overcharge, Overdischarge, Overcurrent, and Overtemperature Protection | |
| Maximum Current 200A | Communication CAN, RS485, Modbus TCP | |
04
Vehicle Charger
| DC Output Voltage 600A | DC Output Current 200A | Power Input AC 3-phase 380V, 60Hz |
| Communication CAN, RS485, Modbus TCP | Charging Method AC Slow (Max. 22 kW) + DC Fast (Max. 125 kW) | |
| Protection Rating IP65 | Connectors Type1, Type2, CCS1, CCS2, CHAdeMO | |
05
Mobile ESS UI
Main Features
| Platform Android, iOS / Web, Local Server |
| Connection Ethernet / VPN / Cloud Integration | |
| Features Map Integration, Lightweight App / Dashboard Layout, Multi-Device Support |

Headquarters R&D Center
#506, The First Tower, 10 Dongtandaero 21-gil, Yeongcheon-dong, Hwaseong-si, Gyeonggi-do
Factory
#510, The First Tower, 10 Dongtandaero 21-gil, Yeongcheon-dong, Hwaseong-si, Gyeonggi-do
2nd R&D - Yonsei University
Room 212-A-2, Engineering Hall, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul
3rd R&D - KAIST Mobility Center
Room 207(208), 2F, 6 Cheomdansandan 5-gil, Hongbuk-eup, Hongseong-gun, Chungcheongnam-do
![]() | ||
Headquarters R&D Center #506, The First Tower, 10 Dongtandaero 21-gil, Yeongcheon-dong, Hwaseong-si, Gyeonggi-do Factory #510, The First Tower, 10 Dongtandaero 21-gil, Yeongcheon-dong, Hwaseong-si, Gyeonggi-do | 2nd R&D - Yonsei University Room 212-A-2, Engineering Hall, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul 3rd R&D - KAIST Mobility Center Room 207(208), 2F, 6 Cheomdansandan 5-gil, Hongbuk-eup, Hongseong-gun, Chungcheongnam-do |